Compatible *Zimmer STRAIGHT MULTI UNIT ABUTMENT - *Zimmer Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platform 3.5 Titanium Grade 5 View
Compatible *Zimmer STRAIGHT ANATOMICAL MULTI UNIT ABUTMENT - *Zimmer Straight Anatomical MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platform 3.5 Titanium Grade 5 View
Compatible *Astra STRAIGHT MULTI UNIT ABUTMENT - *Astra Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.5/4.0 - 4.5/5.0 Titanium Grade 5 View
Compatible *Nobel CC STRAIGHT MULTI UNIT ABUTMENT - *Nobel Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.5 | 4.3 Titanium Grade 5 View
Compatible *Certain STRAIGHT MULTI UNIT ABUTMENT - *Certain Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.4 | 4.1 Titanium Grade 5 View
Compatible *Sweden & Martina STRAIGHT MULTI UNIT ABUTMENT - *Sweden & Martina Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.3 | 3.8 | 4.25 | 5.0 Titanium Grade 5 View
Compatible *Zimmer ANGLED ANATOMICAL MULTI UNIT - *Zimmer + SCREW Angled Mua is mainly used for the "All on Four" technique when we need to parallelize non-parallel implants. Recommended torque 30 N.cm Platform 3.5 Titanium Grade 5 Driver: Hexagonal 1.25 Delivered with the screw View
Compatible *Astra ANGLED MULTI UNIT - *Astra + SCREW Angled Mua is mainly used for the "All on Four" technique when we need to parallelize non-parallel implants. Recommended torque 30 N.cm Platforms 3.5/4.0 - 4.5/5.0 Titanium Grade 5 Driver: Hexagonal 1.30 Delivered with the screw View
Compatible *Nobel CC ANGLED MULTI UNIT - *Nobel + SCREW Angled Mua is mainly used for the "All on Four" technique when we need to parallelize non-parallel implants. Recommended torque 30 N.cm Platforms 3.5 | 4.3 Titanium Grade 5 Driver: Unigrip Delivered with the screw View
Compatible *Certain ANGLED MULTI UNIT ABUTMENT - *Certain + SCREW Where angulation correction is required, the Multi Unit angled abutments provide an advanced solution for restoration on multiple implants. Recommended torque 30 N.cm Platforms 3.4 | 4.1 Titanium Grade 5 Driver: Hexagonal 1.20 View
Compatible *Sweden & Martina ANGLED MULTI UNIT ABUTMENT - *Sweden & Martina + SCREW Where angulation correction is required, the Multi Unit angled abutments provide an advanced solution for restoration on multiple implants. Recommended torque 30 N.cm Titanium Grade 5 Driver: Hexagonal 1.27 View
Compatible ESA shore* ANGLED MULTI UNIT ABUTMENT - *ESA Shore + SCREW Where angulation correction is required, the Multi Unit angled abutments provide an advanced solution for restoration on multiple implants. Recommended torque 30 N.cm Titanium Grade 5 Driver: Hexagonal 1.20 View