Compatible *Straumann Bone Level CASTABLE ABUTMENT CR-CO - *Straumann + SCREW S360 The castable abutment based on cobalt chrome offers a convenient solution with extraordinary flexibility for both the technician and the modeler, thanks to its gingival emergence profile adaptable according to individual needs. Recommended Torque 30 N.cm Platform 4.8 CR-CO Driver: Torx Delivered with the... View
Compatible *Sweden & Martina CASTABLE ABUTMENT CR-CO - *Sweden & Martina + SCREW The castable abutment based on cobalt chrome offers a convenient solution with extraordinary flexibility for both the technician and the modeler, thanks to its gingival emergence profile adaptable according to individual needs. Recommended torque 30 N.cm Platforms 3.3 | 3.8 | 4.25 | 5.0 CR-CO Driver: Hexagonal 1.27 Delivered with the screw View
Compatible M.U.A. VITE CORTA TORRETTA TITANIO MULTI UNIT ANGOLATO X522 Torque consigliato 15 N.cm Vite Corta per Torretta Titanio Multi Unit Angolato Titanio GRADO 5 Driver: Esagono 1.20 View
Compatible M.U.A. TORRETTA TITANIO PER OCTA 4.8 + VITE ESTTOK Consegnato con la vite in titanio Torque consigliato 15 N.cm Torretta in Titanio per Octa + Vite Titanio GRADO 5 Driver: Esagono 1.20 View
Compatible M.U.A. VITE TORRETTA M.U.A. OCTA ESVPO Torque consigliato 30 N.cm Vite Per Moncone Dritto Esagono 1.25 Titanio GRADO 5 Driver: Esagono 1.25 View
Compatible *Zimmer STRAIGHT MULTI UNIT ABUTMENT - *Zimmer Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platform 3.5 Titanium Grade 5 View
Compatible *Zimmer STRAIGHT ANATOMICAL MULTI UNIT ABUTMENT - *Zimmer Straight Anatomical MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platform 3.5 Titanium Grade 5 View
Compatible *Astra STRAIGHT MULTI UNIT ABUTMENT - *Astra Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.5/4.0 - 4.5/5.0 Titanium Grade 5 View
Compatible *Nobel CC STRAIGHT MULTI UNIT ABUTMENT - *Nobel Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.5 | 4.3 Titanium Grade 5 View
Compatible *Certain STRAIGHT MULTI UNIT ABUTMENT - *Certain Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.4 | 4.1 Titanium Grade 5 View
Compatible *Sweden & Martina STRAIGHT MULTI UNIT ABUTMENT - *Sweden & Martina Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 3.3 | 3.8 | 4.25 | 5.0 Titanium Grade 5 View
Compatible *Straumann Bone Level STRAIGHT MULTI UNIT ABUTMENT OCTA - *Straumann Straight MUA is mainly used for the All on Four technique; its characteristic is that of releasing the forces to the plant itself. Recommended torque 30 N.cm Platforms 4.8 Titanium Grade 5 View
External Hexagon ANGLED MULTI UNIT ABUTMENT - External Hexagon B617 Where angulation correction is required, the Multi Unit angled abutments provide an advanced solution for restoration on multiple implants. Recommended torque 30 N.cm Platforms 3.3 | 4.1 | 5.0 Titanium Grade 5 Driver: Hexagonal 1.20 View
Compatible *Zimmer ANGLED MULTI UNIT - *Zimmer + SCREW Angled Mua is mainly used for the "All on Four" technique when we need to parallelize non-parallel implants. Recommended torque 30 N.cm Platform 3.5 Titanium Grade 5 Driver: Hexagonal 1.25 Delivered with the screw View
Compatible *Zimmer ANGLED ANATOMICAL MULTI UNIT - *Zimmer + SCREW Angled Mua is mainly used for the "All on Four" technique when we need to parallelize non-parallel implants. Recommended torque 30 N.cm Platform 3.5 Titanium Grade 5 Driver: Hexagonal 1.25 Delivered with the screw View
Compatible *Astra ANGLED MULTI UNIT - *Astra + SCREW Angled Mua is mainly used for the "All on Four" technique when we need to parallelize non-parallel implants. Recommended torque 30 N.cm Platforms 3.5/4.0 - 4.5/5.0 Titanium Grade 5 Driver: Hexagonal 1.30 Delivered with the screw View
Compatible *Nobel CC ANGLED MULTI UNIT - *Nobel + SCREW Angled Mua is mainly used for the "All on Four" technique when we need to parallelize non-parallel implants. Recommended torque 30 N.cm Platforms 3.5 | 4.3 Titanium Grade 5 Driver: Unigrip Delivered with the screw View
Compatible *Certain ANGLED MULTI UNIT ABUTMENT - *Certain + SCREW Where angulation correction is required, the Multi Unit angled abutments provide an advanced solution for restoration on multiple implants. Recommended torque 30 N.cm Platforms 3.4 | 4.1 Titanium Grade 5 Driver: Hexagonal 1.20 View
Compatible *Sweden & Martina ANGLED MULTI UNIT ABUTMENT - *Sweden & Martina + SCREW Where angulation correction is required, the Multi Unit angled abutments provide an advanced solution for restoration on multiple implants. Recommended torque 30 N.cm Titanium Grade 5 Driver: Hexagonal 1.27 View
Compatible ESA shore* ANGLED MULTI UNIT ABUTMENT - *ESA Shore + SCREW Where angulation correction is required, the Multi Unit angled abutments provide an advanced solution for restoration on multiple implants. Recommended torque 30 N.cm Titanium Grade 5 Driver: Hexagonal 1.20 View
Compatible *Zimmer copy of MULTI UNIT DRITTO P 4.1 LOC Torque consigliato 30 N.cm Multi Unit Dritto Titanio GRADO 5 View